‍Choromatogheraphy

In column chromatography, the stationary phase, a solid adsorbent, is placed in a vertical glass (usually) column and the mobile phase, a liquid, is added to the top and flows down through the column (by either gravity or external pressure). Column chromatography is generally used as a purification technique: it isolates desired compounds from a mixture.

The mixture to be analyzed by column chromatrography is applied to the top of the column. The liquid solvent (the eluent) is passed through the column by gravity or by the application of air pressure. An equilibrium is established between the solute adsorbed on the adsorbent and the eluting solvent flowing down through the column. Because the different components in the mixture have different interactions with the stationary and mobile phases, they will be carried along with the mobile phase to varying degrees and a separation will be achieved. The individual components, or elutants, are collected as the solvent drips from the bottom of the column.

Column chromatography is separated into two categories, depending on how the solvent flows down the column. If the solvent is allowed to flow down the column by gravity, or percolation, it is called gravity column chromatography. If the solvent is forced down the column by positive air pressure, it is called flash chromatography, a "state of the art" method currently used in organic chemistry research laboratories The term "flash chromatography" was coined by Professor W. Clark Still because it can be done in a “flash."

The Adsorbent

Silica gel (SiO2) and alumina (Al2O3) are two adsorbents commonly used by the organic chemist for column chromatography. These adsorbents are sold in different mesh sizes, as indicated by a number on the bottle label: “silica gel 60” or “silica gel 230-400” are a couple examples. This number refers to the mesh of the sieve used to size the silica, specifically, the number of holes in the mesh or sieve through which the crude silica particle mixture is passed in the manufacturing process. If there are more holes per unit area, those holes are smaller, thus allowing only smaller silica particles go through the sieve. The relationship is: the larger the mesh size, the smaller the adsorbent particles.

Adsorbent particle size affects how the solvent flows through the column. Smaller particles (higher mesh values) are used for flash chromatography, larger particles (lower mesh values) are used for gravity chromatography. For example, 70–230 silica gel is used for gravity columns and 230–400 mesh for flash columns.

Alumina is used more frequently in column chromatography than it is in TLC. Alumina is quite sensitive to the amount of water which is bound to it: the higher its water content, the less polar sites it has to bind organic compounds, and thus the less “sticky” it is. This stickiness or activity is designated as I, II, or III, with I being the most active. Alumina is usually purchased as activity I and deactivated with water before use according to specific procedures. Alumina comes in three forms: acidic, neutral, and basic. The neutral form of activity II or III, 150 mesh, is most commonly employed.

Silica gel and alumina are the only column chromatography adsorbents used in the CU organic chemistry teaching labs; please refer to the references for information on other column chromatography adsorbents.

The Solvent

The polarity of the solvent which is passed through the column affects the relative rates at which compounds move through the column. Polar solvents can more effectively compete with the polar molecules of a mixture for the polar sites on the adsorbent surface and will also better solvate the polar constituents. Consequently, a highly polar solvent will move even highly polar molecules rapidly through the column. If a solvent is too polar, movement becomes too rapid, and little or no separation of the components of a mixture will result. If a solvent is not polar enough, no compounds will elute from the column. Proper choice of an eluting solvent is thus crucial to the successful application of column chromatography as a separation technique. TLC is generally used to determine the system for a column chromatography separation. The choice of a solvent for the elution of compounds by column chromatography is covered in the Chromatography Overview section.

Often a series of increasingly polar solvent systems are used to elute a column. A non-polar solvent is first used to elute a less-polar compound. Once the less-polar compound is off the column, a more-polar solvent is added to the column to elute the more-polar compound.

Interactions of the Compound and the Adsorbent

Compounds interact with the silica or alumina largely due to polar interactions. These interactions are discussed in the section on TLC.

Analysis of Column Eluants

If the compounds separated in a column chromatography procedure are colored, the progress of the separation can simply be monitored visually. More commonly, the compounds to be isolated from column chromatography are colorless. In this case, small fractions of the eluent are collected sequentially in labeled tubes and the composition of each fractions is analyzed by thin layer chromatography. (Other methods of analysis are available; this is the most common method and the one used in the organic chemistry teaching labs.)

Procedures

Column chromatography procedures are illustrated with photographs on the procedure page.

 

 


مطالب مشابه :


لیست دانشگاههای آزاد و دولتی

--- دانشگاه آزاد اسلامی واحد آبادان --- - لیست دانشگاههای آزاد و دولتی - رشته ی مهندسی شیمی




‍Choromatogheraphy

دانشگاه آزاد اسلامی واحد آبادان - ‍Choromatogheraphy - پژوهشکده مجازی گروه مهندسی شیمی دانشگاه آزاد




چگونگي تصفيه نفت خام

دانشگاه آزاد اسلامی واحد آبادان - چگونگي تصفيه نفت خام - پژوهشکده مجازی گروه مهندسی شیمی




ثبت نام کنکور کارشناسی ارشد دانشگاه آزاد اسلامی سال 1392

دانشگاه آزاد اسلامی واحد آبادان - ثبت نام کنکور کارشناسی ارشد دانشگاه آزاد اسلامی سال 1392




ثبت نام بدون آزمون

--- دانشگاه آزاد اسلامی واحد آبادان --- - ثبت نام بدون آزمون - رشته ی مهندسی شیمی گرایش های




خلاصه ای از آیین نامه ی آموزشی دانشگاه

--- دانشگاه آزاد اسلامی واحد آبادان --- - خلاصه ای از آیین نامه ی آموزشی دانشگاه - رشته ی مهندسی




برنامه زمان بندی ترم نیمسال دوم 1390-1391

دانشگاه آزاد اسلامی واحد آبادان - برنامه زمان بندی ترم نیمسال دوم 1390-1391 - پژوهشکده مجازی




مقاله باران شدن اولین همایش ملی نفت - گاز - پتروشیمی اهواز توسط اساتید و دانشجویان گروه

دانشگاه آزاد اسلامی واحد آبادان - مقاله باران شدن اولین همایش ملی نفت - گاز - پتروشیمی اهواز




برچسب :